INPUT PARAMETERS | ||||||||||||
Number of input connection phases | 1 Phase | |||||||||||
Input voltage correction range | Min. 11 OV AC – Max 300 V AC |
|||||||||||
Board supply operating voltage | 75 V. AC | |||||||||||
Continuous uptime at full load | Continuous 7/24 | |||||||||||
Operating frequency | 50 / 60 Hz. | |||||||||||
OUTPUT PARAMETERS | ||||||||||||
Corrected output voltage | 200 V AC…. 220 V AC.. 240 V AC (adjustable from the menu) | |||||||||||
Correction speed | Frequency 50 = 20ms – Frequency 60 = 50 ms | |||||||||||
Output tolerance | 1% %9% (Adjustable from the menu.) | |||||||||||
Output delay time setting | 1 sec 1 Os n (Adjustable from menu.) | |||||||||||
Output upper limit shutdown | 242 V AC Adjustable from menu (Protected models) | |||||||||||
Output lower limit shutdown | 75 V AC Adjustable from menu (Protected models) | |||||||||||
Overload | 1O Seconds to 200 At Load | |||||||||||
Efficiency | 98% at full load | |||||||||||
GENERAL PARAMETERS | ||||||||||||
Mechanical By-Pass | With Pako switch | |||||||||||
Automatic By-Pass | Optional | |||||||||||
Cooling System | Smart Fan | |||||||||||
Harmonic Distortion | None | |||||||||||
Input voltage – Output voltage measurement | TRUERMS (Adjustable from menu) | |||||||||||
Display | 2×3 Digit red led display | |||||||||||
ENVIRONMENTAL CONDITIONS | ||||||||||||
Operating temperature | –l 0 C / + S0 C | |||||||||||
Bound humidity | <90% DiN | |||||||||||
Working height | <3000 Meter | |||||||||||
Acoustic level | <50 dB | |||||||||||
Microprocessor Regulator Wide Model Selection More than 200 standard models from 1 kVA to 40 kVA single-phase, from 1 kVA to 2000 kVA three-phase. Wide Voltage Option In standard models, single-phase 150-250 volt input is 220 volt output. Three-phase 275-450 volt input380 volt output. Production is made in desired voltages upon order. Regulation Speed Regulation speed (average) for standard models is 200 volts/second | ||||||||||||
Output Regulation Within the capacity of the regulator, it does not fluctuate in loads from zero (o) to maximum and voltage changes during load, does not disturb the mains frequency, the output is full sinusoidal, the sensitivity can be adjusted between 1-5%. The power factor of the load is insignificant as long as the regulator stays within the kVA limits. Mechanical Construction All models can be used in every field as they are produced in heavy industrial type. Cooled, roller brush system prevents burning and abrasion in the coal. Brushes do not spark/arc during regulation. High Efficiency The average efficiency is higher than 97%. Since Redsan Electronic Regulators are manufactured with high quality silicon sheet and electrolytic copper, idle loss is minimum. Operating Temperature For indoor areas from -10°C to +40°C, extra air cooling is required or regulators should be used below capacity. Regulators should not be used in extremely humid and acidic environments. Over Voltage Protection Unit (optional) * In case of voltages above the voltage capacity of the regulator * When the regulator is activated at low voltages, if the mains voltage is cut off and comes back as a high voltage * In case the regulator works in a dirty environment in time and fails or gives irregular voltage The regulator cuts the output voltage for 8 seconds and gives output when the regulation is completed. It does not output in case of a malfunction. Phase Protection Unit In three-phase regulators, if one of the 3 phases is cut off, it cuts the output completely. Automatically activates when the phase is restored and gives output. |
Monophase 1-200 KVA
- Prices Include Shipping Fee.
- Prices Exclude VAT.
- 24/7 Support Opportunity
0
People watching this product now!
Category: Single Phase
Description
Be the first to review “Monophase 1-200 KVA” Cancel reply
You must be logged in to post a review.