Features
- VFI-SS-111 Standard Introduction Voltage and Frequency Independent Operation
- DSP Controlled IGBT Rectifier
- IGBT Inverter – Battery Charging System
- Wide Input Voltage Range
- High Input Power Factor (>0.99)
- Up to 94% high efficiency in online mode
- Up to 98% high efficiency in Eco-Mode
- True Sine Wave Output Waveform
- Low Harmonic Distortion
- Static and Manual Bypass
- Electromagnetic and RFI Protection
- Network, charging system, battery status and output voltage information via digital panel
- Long battery life with smart charging system
- Monitoring and secure shutdown via RS232
- Communication via serial port, smart relay contact outputs
- Quiet operation with intelligent fan speed control
- Custom production input/output values as required
Applications
- Information Centres
- Factories
- Medical Devices
- Emergency Systems (Alarm)
- Communication Devices
- Server Rooms
- Industrial Applications
- Personal Computers
- Small Computer Network
- Network Systems
Advantages
-
- The Latest Technology
- Economical Use
- Clean and Stable Output Voltage
- Overload and Short Circuit Protection
- Remote Management
- Adjustable Values
- Generator Compatibility
Technical Specifications
| POWER | 10 kVA | 20 kVA | 30 kVA | 40 kVA | 45 kVA | 60 kVA | 80 kVA | 100 kVA | 120 kVA |
|---|---|---|---|---|---|---|---|---|---|
| INTRODUCTION | |||||||||
| Voltage | 380 / 400 / 415 VAC 3-phase + N | ||||||||
| Voltage Tolerance | ± 5% – 20% (Adjustable) | ||||||||
| Power Factor | ≥0.99 | ||||||||
| Frequency | 50 / 60 Hz ± 5% | ||||||||
| THDi | < %4 | ||||||||
| BYPASS | |||||||||
| Dual Input Connection | Standard | ||||||||
| Voltage | 380 / 400 / 415 VAC 3 Phase + N | ||||||||
| Voltage Tolerance | ±10% (Adjustable) | ||||||||
| Frequency | 50/60 Hz | ||||||||
| Frequency Tolerance | ±10% (Adjustable) | ||||||||
| OUTPUT | |||||||||
| Voltage | 380 / 400 / 415 VAC 3-phase + N | ||||||||
| Voltage Tolerance | ±1% (Static load), According to VFI-SS-111 under Dynamic load | ||||||||
| Frequency | 50Hz / 60Hz (Optional) | ||||||||
| Frequency Tolerance | ±0.1% (Free running), ±4% (Grid synchronised, adjustable ±5%) | ||||||||
| Power Factor | 0.8 (Optional 0.9 or 1) | ||||||||
| THDv | < 3% linear load, < 5% non-linear load (IEC/EN 62040-3) | ||||||||
| Crest Factor | 3:1 | ||||||||
| EXCESS LOAD CAPACITY | |||||||||
| 100 – 110% | Operates continuously in normal position | ||||||||
| 110 – 125% | 10 min. | ||||||||
| 125 – 150% | 1 min. | ||||||||
| >150% | Continuous bypass position | ||||||||
| AKU | |||||||||
| Number of Batteries | 60 Units (+405VDC / -405VDC) | ||||||||
| Battery Compartment | Internal | External | |||||||
| Battery Protection | Deep discharge protection | ||||||||
| Battery Test | Automatic / Manual | ||||||||
| YIELD | |||||||||
| Online Mode (Full Load) | > 92% | ||||||||
| Eco-Mode (Full Load) | > 98% | ||||||||
| GENERAL | |||||||||
| Topology | True Online – Double Conversion, IGBT Rectifier and Inverter | ||||||||
| Control Technology | 3 DSP processors, SPWM | ||||||||
| Indicators | Graphic LCD panel, Mimic diagram, Control buttons, Warning LED error indicators | ||||||||
| OPTIONS | |||||||||
| Parallel Work | 6 Unit up to | ||||||||
| Communication | SNMP, RS232, RS485, MODBUS | ||||||||
| Remote Monitoring | SNMP view, UPSMon, Remote Panel | ||||||||
| Dry Contact Relay Outputs | Programmable 3 Dry Contacts | ||||||||
| Special Inputs | Generator, Battery temperature control, Remote Emergency Power Off (EPO) | ||||||||
| WORKING CONDITIONS | |||||||||
| Operating Temperature | 0°C – 40°C | ||||||||
| Humidity | 0% – 95% (Non-condensing) | ||||||||
| Altitude | ≤ 2000 m | ||||||||
| Noise | < 65 dB(A) | ||||||||
| PHYSICAL CONDITIONS | |||||||||
| Dimensions (WxHxD) mm | 350x795x1110 | 500x806x1213 | 550x800x1335 | ||||||
| Weight (kg) | 82 | 85 | 90 | 100 | 110 | 165 | 172 | 290 | 315 |
| Protection Class | IP 20 | ||||||||
10 – 120 kVA Online UPS General Introduction
10 – 120 kVA Online UPS series; medium and large scale businesses, data centres and industrial facilities with high power requirements a16> tailored designed professional uninterruptible power solution for. True online double conversion topology completely isolates the energy coming from the grid by isolating it completely and thus a35> devices pure and stable output is provided.
This series accommodates projects of varying scales with a wide range of capacity options, starting from 10 kVA and extending up to 120 kVA. It offers maximum security, high efficiency and long-term performance in environments where critical infrastructure must be protected.
True Online Dual Conversion Technology
In online UPS systems, power continuously passes through the rectifier and inverter. This structure filters out sudden voltage fluctuations, frequency distortions, harmonics and micro-interruptions before they reach the devices. Operating in accordance with the VFI-SS-111 standard, it produces a stable output independent of the input voltage and frequency.
IGBT rectifier and IGBT inverter technology provides high-performance, low-loss energy conversion. This offers significant advantages in terms of both device safety and energy efficiency.
High Efficiency and Energy Savings
It provides significant energy savings for businesses with an efficiency rate exceeding 92% in online mode and up to 98% in Eco mode. Thanks to its high input power factor (>0.99) and low harmonic distortion (THDi < 4%), it places minimal load on the grid.
The intelligent fan speed control system optimises energy consumption and ensures quiet operation. This feature provides comfortable use, particularly in office and data centre environments.
Parallel Processing and Scalable Architecture
This series offers support for up to six units operating in parallel. This enables capacity expansion or redundancy to be provided. As businesses grow, the power infrastructure can be flexibly expanded.
Parallel system structure thanks to high continuity requiring data a8> centres and production facilities uninterrupted operation capability provides.
Smart Battery Management System
Advanced charging technology and deep discharge protection maximise battery life. Automatic and manual battery test functions ensure system safety is constantly monitored.
Long backup times can be achieved with the external battery cabinet option. This feature offers a significant advantage, particularly in areas experiencing prolonged power outages.
Advanced Communication and Remote Management
Thanks to SNMP, RS232, RS485 and MODBUS communication protocols, the system can be monitored and managed remotely. IT teams can provide centralised control with software support such as UPSMon, SNMP View and Remote Panel.
The safety and integration level has been enhanced with programmable dry contact relay outputs and remote emergency power-off (EPO) inputs.
Industrial Durability and Safety
With its robust body construction featuring IP20 protection class, it is suitable for industrial environments. It delivers stable performance in different environmental conditions with an operating temperature range of 0°C to 40°C and a non-condensing humidity tolerance of up to 95%.
Thanks to the static and manual bypass feature, the load can be transferred to the bypass line without interruption during maintenance or malfunction.
Why should you choose a 10–120 kVA online UPS?
Thanks to its high capacity range, robust hardware infrastructure and advanced protection systems, this series is the ideal energy solution for data centres, factories, hospitals and large-scale businesses.
True online double conversion technology, high efficiency, parallel operation support and remote management features safeguard your business’s energy infrastructure. It provides uninterrupted, clean and reliable power for your critical systems.